1 MAINTENANCE
Except for fuse replacement, the 9314E should require no maintenance.
Replacing the Fuse
A pair of fuses are mounted in the power entry module. To replace fuses, follow the instruc-
tions given below:
1. Unplug the 9314E from power source and remove power cord from the back
panel.
2. Remove the fuse holder by pushing down on the center tab and pulling out.
3. Remove the faulty fuses and replace with one of a similar rating, (5 x 20 mm, .125
Amp).
4. Reinstall the fuse holder.
5. Reattach the power cord.