Page 56 9530/8530 Manual Version 4.8
Mode: Disabled
Change Trigger Mode
Mode: Triggered
Level: 2.50 Volts
Edge: Rising/Falling Edge
Mode: Dual Trig
Level: 2.50 Volts
Edge: Rising/Falling Edge
Gate Menu
When the Dual Trigger option is evoked under the Trigger menu the Gate menu changes to allow
the user to only change the level and edge parameters.
Mode: Dual Trig.
Level: 2.50 Volts
Edge: Rising/Falling Edge
13. Appendix F – Impedance
Matching
Outputs
TZ50 Impedance Matching Output Module
This module option allows a user to have a 50 Ω load on the output while maintaining output
amplitude of at least 4 Volts while in the TTL/CMOS mode. All other functionality of the module is
the same as the AT20 modules, including output while using the Adjustable Mode Function of the
channels.
TTL/ADJUSTABLE OUTPUTS
4.0 Volts typical into 50 Ω
Jitter – Channel to Channel
200 mA typical, 400 mA max (short pulses)
*Note: The TZ50 module has significant overshoot and ringing through high
impedance (see figure).